The award winning Power Platform® 4300 sets the industry standard for power analyzers. With its four differential voltage channels and four independent current channels, the PP-4300 is the ideal tool for preventive maintenance, troubleshooting, performing long-range power quality and energy surveys, and proactive planning of your power system infrastructure. The key to the PP-4300's success is its versatility, ease-of-use and high performance. Using interchangeable TASKCards® the PP-4300 can serve as a full featured, 3-phase power quality instrument, energy management tool, harmonics analyzer, inrush/fault recorder, and data logger. Each TASKCard performs a different set of functions, enabling you to choose the TASKCard that fits the job. Plus, each TASKCard guides you through setup and usage instructions so that you can hit the ground running. |
![]() |
How do I select the TASKCard that's right for me?
We've prepared a simple chart based on our user's most common applications.
| Applications | 808 Energy | PQ Lite | Multi-DAQ |
| PQ Surveys | * |
![]() | |
| Energy Reduction Studies | * |
![]() |
![]() |
| Fault Recorder | ![]() | ||
| Harmonic Surveys | ![]() |
||
| Inrush | ![]() | ||
| Motor/generator testing | ![]() |
* | |
| Breaker monitoring | ![]() |
* | |
| Power surveys | * |
![]() |
![]() |
| Data logger | ![]() |
* | |
| * Denotes preferred TASKCard for application. | |||
| Compare Specifications |
| Attributes | TASK808 | PQLite | Multi-DAQ |
| Circuit Type | |||
| Single Phase | ![]() |
![]() |
![]() |
| Three Phase | ![]() |
![]() |
![]() |
| Real-Time | |||
| Scope Display | ![]() |
![]() |
![]() |
| Harmonics Display | ![]() |
![]() |
![]() |
| Power Quality - Triggers | |||
| Cycle-by-cycle analysis | ![]() |
![]() | |
| Sags/swells | ![]() |
![]() | |
| Neutral-to-ground | ![]() |
![]() | |
| RMS current | ![]() |
![]() | |
| Transients-current | ![]() |
![]() | |
| Transients-voltage | ![]() |
![]() | |
| Transients-waveshape (V&I) | ![]() | ||
| Transients-peak detected (V&I) | ![]() |
||
| Harmonics | ![]() |
||
| Power/Energy | |||
| W, VA, VAR | ![]() |
![]() |
![]() |
| Power factor-true | ![]() |
![]() |
![]() |
| Displacement power factor | ![]() |
![]() |
![]() |
| Demand (kW, kVA) | ![]() |
![]() |
![]() |
| Energy (kWh) | ![]() |
![]() |
![]() |
| Harmonics | |||
| THD/Spectrum analysis | ![]() |
![]() |
![]() |
| Crest factor | ![]() |
||
| Transformer K-factor | ![]() |
||
| Transformer derating | ![]() |
||
| Special Measurements | |||
| Motor inrush/transformer energization | ![]() | ||
| Unbalance | ![]() |
||
| DC voltage | ![]() |
![]() |
![]() |
| Cross trigger (internal) | ![]() |
![]() | |
| Fault recording | ![]() |
![]() | |
| Other | |||
| Dran-View Software | ![]() |
![]() |
![]() |
| Serial (RS232) Communications | ![]() |
![]() |
![]() |
| Onboard Memory | ![]() |
![]() |
![]() |