Model 61000 Specifications Summary
Note: Please see brochure specifications page for detailed specifications and measured parameters.
General
- Operating Temperature: -10º to 60º C
- Storage Temperature: -40º to 85º C
- Humidity: 10 to 95% non-condensing
- System Time Clock-Crystal controlled-1 ms resolution
- Power supply: 12VDC, 15 minute internal UPS, AC supply: 90-264 VAC 47-63 Hz, Optional 125VDC, 220VDC, 48VDC
- Standard 10/100BaseT Ethernet, RS232, RS485 interfaces. XML, HTTP, Modbus communications
- Memory 1GB, internal
Compliance
- CE, ISO9001 registered factory
- Measurements: IEC61000-4-30 Class A, IEC61000-3-6/7, IEEE1159, IEEE519, IEEE1453, EN50160, NVE
Voltage Modules
- (4) differential inputs, AC/DC, 512 samples/cycle synchronous sampling
- Full Scale Accuracy: 0-600V 0.1% reading +/- 0.05% full scale, 7KHz bandwidth for low/medium frequency transients. 100-300V AC 0.1% reading for IEC61000-4-30 Class A
- Choice of connections: Screw terminals, safety connectors, D connector for use with (optional) remote pod with screw terminals. Choose one.
Current Modules
- (4) differential inputs, AC/DC, 512 samples/cycle
- Accuracy: 0.1% reading +/- 0.05% full scale, 3KHz bandwidth for low/medium frequency transients.
- Choice of connections: Dranetz-BMI 'TR' connector, D connector for use with (optional) remote pod with screw terminals. Choose one.
Digital Input Module
- Channels: (8), Sampling: 1KHz. Range: 0-135V AC/DC, Triggers: Edge, level
- Connections: Screw terminals
|