8010/8020
The 8010 PQNode is permanently installed at one location; the 8020 PQNode can be transported for monitoring several locations. Otherwise, their performance and specifications are identical.
Features & Highlights
- Setting and monitoring utility power quality standards
- Co-gen and other contract compliance monitoring
- Substation monitoring
- Volts and amps (true RMS)
- rms sags, swells, interruptions
- rms min/average/max strip charts
- Waveshape faults
- High-speed impulses
- Outages and cold-load pickup
- Frequency
- Periodic snapshots of kVA, kVAR, true PF, dPF
- Simultaneous sampling of voltage and current on all phases
|
|
| Specifications |
| Voltage Inputs |
Phase A, B, C, Neutral, and Ground (supports single phase, split single phase, 3-phase 4-wire wye, 3-phase 3-wire delta) |
|
| Current Inputs |
Phase A, B, C, and Neutral using built-in 25 Amp (pk), 10 amp RMS pass-though CT's |
|
| Voltage Measurements |
0 - 600 Vrms (±1,000 Vpk) or 0 - 170 Vrms (±250 Vpk), user selected 50/60 Hz
|
|
| Voltage Transients |
50 - 6000Vpk Peak detection, IEEE 587 type A and B Accuracy: ±5% reading ±5% full scale |
|
| Current measurements |
0.01 Arms - 2.00 Arms (±5 Apk) or 0.1 Arms - 10.0 Arms (±25 Apk), user selected 50/60 Hz |
|
| Sampling Rate |
256 samples per cycle, continuous on all voltage channels; 128 samples per cycle, continuous on all current channels; Phase-locked sampling technique employed |
|
| Harmonic Measurements |
Through 127th voltage harmonic, 63rd current harmonic at 50/60 Hz |
|
| Triggers |
Voltage-only, waveshape fault, swell, sag, interruption, impulse, periodic waveshape capture, cold load pickup |
|
| Pre- and Post-Trigger |
0 - 15 cycles voltage and current, user selectable. Additional post-trigger rms data available on swell, sags, and cold-load pickup. |
|
| Instrument Power |
90 Vrms - 250 Vrms, 45 Hz - 65 Hz Power factor > 0.97 Power consumption < 40 VA Impulse tolerance 6 kV Suitable for attaching directly to monitored circuit. |
|
| Environment |
Optional NEMA-4X Rain-,dust-,ice-resistant enclosure -22°F to 122°F (-30°C to +50°C) Humidity 0% - 95% non-condensing. |
|
| PC Software |
PASS (limited support in PES) |
|
| Certifications |
FCC, ISO-9001 |
|
|
| Typical Applications |
| Outdoor Service |
Utilities mount 8010 PQNodes outdoors on power poles. Regardless of weather, the 8010 provides detailed, accurate, standard-setting power quality data. |
 |
| Indoor Service |
Indoor mounting of the 8010 PQNode at substations and critical customer loads works well, too. Note the neat, easy-to-use built-in current transformers; just pass the 0 - 10 Amp conductor through the insulated tube, and the 8010 PQNode will take care of the rest. |
 |
|
| Options & Accessories |
| Communications Option |
Internal modem with error-correcting, data compressing and surge protection. |
|
| 15 Minute Battery |
B-801 provides 15 minutes operation in the event of a power failure. |
|
| 1 Hour Battery |
B-802 provides one hour operation in the event of power failure. |
|
| 8 Hour Battery |
B-803 provides 8 hours of operation in the event of power failure. |
|
|
|
|
|
|
Login | Special Offers
| Quick Tech Tips |
| Model 3030a: Unexpected hourly reports ...more |
| Model 130: Won't Answer More Than One Phone Call ...more |
| Quick FAQ's |
| When an interruption occurs, when does my 3100 PQNode/PQPager call me when power is interrupted, or when it is restored? ...more |
| How many waveform snapshots can the 3100 PQNode/PQPager store? ...more |
|